The majority of the requirements related to attic ventilation have not changed much from the previous editions.
Attic ventilation requirements canada.
It is important that air movement occurs and is not impeded by any framing members of the.
After air sealing attic ventilation is your second line of defence against the water vapour that may have found its way into the attic.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
The following are the requirements taken directly from the irc.
Attic ventilation works on the principle that heated air naturally rises primarily utilizing two types of vents.
Intake vents located at the lowest part of the roof under the eaves.
Careful attention to the need for adequate ventilation is necessary when water and vapour impermeable roof covers are applied over attic and roof spaces.
Ridge static attic vents 384 00 minimum sq.
Of net free area of intake needed at or near the soffit.
Attic ventilation serves a number of purposes.
Prior to installing the ridge vent a 1 inch wide strip of roof decking is cut out along both sides of the ridgeline to allow for air movement through the vent.
It reduces summer heat buildup prolonging the life of roofing and reduces air conditioner loads.
When installed as part of a properly balanced when installed as part of a properly balanced attic ventilation system gaf cobra exhaust vent is a shingle over exhaust vent installed at the roof ridge that helps exhaust excess heat and moisture from your attic.
A ridge vent is a ventilation strip that is placed along the ridgeline of the home.
The ontario building code vent requirements 9 19 1 2.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
Vent requirements 1 except as provided in sentence 2 the unobstructed vent area shall be not less than 1 300 of the insulated ceiling area.
2 where the roof slope is less than 1 in 6 or in roofs that are constructed with roof joists the unobstructed vent area shall be not less than 1 150 of the insulated ceiling area.
It comes on an easy to install flexible mesh roll and is hand nailable with no complicated fitting wrapping nail gun adapters.
For the 1 150 attic ventilation requirement simply double the amount of exhaust and intake calculated.